SHENZHEN, China - Dec. 14, 2023 - PRLog -- Board-to-board PCB connector testing & inspection: Observe the voltage applied to the connector does not exceed 50% of its rated voltage. For the installation size of the connector, the length of the soldering feet on the soldered PCB must be exposed to the part of the PCB plate larger than 0.5mm. For more precise connectors, choose models with slightly positioned pins in PCB space for ease of manual soldering. Check if there is any polarity design. Check whether lead is present in the materials used for the board-to-board PCB connector. For small-volume connectors with low-contact pressure, used in low-current and voltage situations, use gold or silver plated connectors to prevent film layer resistance from affecting the signal. Pay attention to the height of the connector after assembly, whether it meets the soldering height of the elements around the PCB.

The connection of board-to-board PCB connectors: The board-to-board plug socket is used to electrically connect two separated circuit boards, which includes the first connector connected to the circuit board and the adapter connector used to connect the first connector in series. The first connector has a first terminal connected to the circuit board and a body for holding the first terminal. The adapter connector has a second terminal and a body for holding the second terminal. The two extended ends of the second terminal can be respectively inserted to cooperate with the first terminal on the two connectors respectively located on the two circuit boards to achieve electrical conduction. One end of the first terminal and the second terminal has a reverse-bent elastic part, and the body and the second terminal can select a suitable extension length according to the standard distance setting of the circuit board.

The troubleshooting of board-to-board PCB connectors: if a product fails, it be identified as wire breakage, product loosening, etc.. Wire breakage in the middle is not very common; most often, it occurs at the connector. The focus of inspection should be on the wires at the sensor and connector sequence to check for looseness, poor contact, and other issues. Open circuit faults caused by poor contact are mostly due to rust on the product's end, dirt entering the terminal or connector socket, which in turn leads to a decrease in contact pressure. To solve this issue, the connector needs to be removed, then reinserted to change its connection status, restoring normal contact.

Contact
Greenconn Corporation
***@greenconn.com

Photo:
https://www.prlog.org/12998494/1
End
Source: » Follow
Email:***@greenconn.com
Tags:board to board PCB connectors
Industry:Electronics, Manufacturing
Location:Shenzhen - Guangdong - China
Subject:Products
Account Email Address Verified     Account Phone Number Verified     Disclaimer     Report Abuse



Like PRLog?
9K2K1K
Click to Share